2.EXPLANATION OF OPERATION MODES FANUC BUILT-IN SPINDLE MOTOR Bis series B-65280EN/05
- 576 -
(3) Other parameters
This item details the parameters common to all operation modes
except the parameters listed in Items (1) and (2) above.
15i 16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
3001 4001 4001
MRDY1
MRDY1 Whether to use the MRDYA signal (machine ready signal)
0 : Does not uses the MRDYA signal (MRDYA = 1 at all times).
1 : Uses the MRDYA signal.
15i 16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
3006 4006 4006
GRUNIT
GRUNIT Sets a gear ratio setting resolution:
0 : 1/100 unit
1 : 1/1000 unit
Select a gear ratio data setting resolution from the following:
(a) Resolution based on motor speed increased by a factor of 100
relative to one spindle rotation
(b) Resolution based on motor speed increased by a factor of 1000
relative to one spindle rotation
Depending on the setting of this parameter, the increment system of
the parameters indicated in the table below changes.
Parameter No.
15i 16i 30i
Description
3056 to 3059 4056 to 4059 4056 to 4059 Spindle-to-motor gear ratio data
NOTE
Usually, use the 1/100 unit (setting "0").
15i 16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
3009 4009 4009
LDTOUT VLPGAN
VLPGAN Velocity control loop gain increment system
0 : Uses ordinary setting.
1 : Divides ordinary setting data by 16 for processing.
NOTE
Usually, set this parameter to 0.
LDTOUT Whether to output the load detection signals (LDT1, LDT2) during
acceleration/deceleration
0 : Does not output the load detection signals during acceleration/
deceleration (standard setting value).
1 : Outputs the load detection signals during acceleration/
deceleration (at all times) when the parameter-set level is
exceeded.