A.SPINDLE PARAMETER TABLE APPENDIX B-65280EN/05
- 642 -
Application
Internal
data No.
F-xxx
15i 16i 30i
bit
Standard
initial setting
data
Contents
MH ML SH SL
Classifi
-cation
Reference
item
#2 Depends on
the model
Motor sensor type O O A App. B
173L 3187 4187 4187 #0 Depends on
the model
Teeth number setting of motor sensor O O A App. B
#1 Depends on
the model
Teeth number setting of motor sensor O O A App. B
#2 Depends on
the model
Teeth number setting of motor sensor O O A App. B
#3 Depends on
the model
Number of motor poles O O C App. B
#4 Depends on
the model
Setting of maximum output during
acceleration/deceleration
O O C App. B
#7 Depends on
the model
Number of motor poles O O C App. B
174H 3188 4188 4188 #0 Depends on
the model
Setting of PWM carrier frequency O O C App. B
#1 Depends on
the model
Setting of PWM carrier frequency O O C App. B
#2 Depends on
the model
Setting of PWM carrier frequency O O C App. B
174L 3189 4189 4189 #2 Depends on
the model
Current dead-band data O O C App. B
#3 Depends on
the model
Current dead-band data O O C App. B
#4 Depends on
the model
Current dead-band data O O C App. B
#5 Depends on
the model
Current dead-band data O O C App. B
#6 Depends on
the model
Current dead-band data O O C App. B
#7 Depends on
the model
Setting of a PWM carrier frequency for low-speed
characteristics area
O C App. B
176H 3192 4192 4192 #3 0 Setting of the smoothing function in feed-forward
control
O O B App. B
#4 0 Setting related to control characteristics on servo
mode
O O B App. B
#6 0 Whether to detect the alarm (SPM alarms 46)
related to feedback of the position detection signal
for threading
O O A App. B
#7 0 Function for newly detecting the one-rotation signal
before entering position control mode
O O A App. B
176L 3193 4193 4193 #0 0 This parameter sets speed integration operation when
differential spindle speed control is exercised.
O O B App. B
#7 0 Setting of shortcut orientation from stop state in
position coder method spindle orientation
O O B App. B
177H 3194 4194 4194 #5 0 Whether to use the velocity command compensation
function during high-speed orientation
O O B App. B
#6 0 High-speed orientation function O O B App. B
177L 3195 4195 4195 #2 1 Whether to use torque clamp at zero speed O O B App. B
#4 0 Setting of the function for switching from high-speed
characteristics to low-speed characteristics with the
speed detection signal SDT = 1 at speed range
switching
O O B App. B
#7 0 Automatic parameter setting function (16i/30i) O O B App. B
178 3196 4196 4196 Depends on
the model
Maximum motor speed O O C App. B
179 3197 4197 4197 150 Speed arrival detection level (SAR) O O B App. B
180 3198 4198 4198 30 Speed detection level (SDT) O O B App. B
181 3199 4199 4199 75 Zero speed detection level (SST) O O B App. B
182 3200 4200 4200 50 Limited torque (TLMH, TLML) O O B App. B
183 3201 4201 4201 83 Load detection level 1 (LDT1) O O B App. B