2.EXPLANATION OF OPERATION MODES FANUC AC SPINDLE MOTOR αi series B-65280EN/05
- 38 -
WARNING
The spindle motor may rotate at the maximum
spindle motor speed specified by this parameter.
Therefore, this parameter must not be set to a
value greater than the maximum rotation speed
indicated by the specification of the spindle motor.
15i 16i 30i
3022 4022 4022
Speed arrival detection level
Unit of data : 0.1%
Valid data range : 0 to 1000
Standard setting value : 150
This parameter sets a speed arrival signal (SARA) detection range.
When the motor speed reaches within ±(setting data/10)% of a
specified speed, the speed arrival signal (SARA) is set to 1.
15i 16i 30i
3023 4023 4023
Speed detection level
Unit of data : 0.1%
Valid data range : 0 to 1000
Standard setting value : 30
This parameter sets a speed detection signal (SDTA) detection range.
When the motor speed is (setting data/10)% of a maximum speed or
less, the speed detection signal (SDTA) is set to 1.
15i 16i 30i
3024 4024 4024
Speed zero detection level
Unit of data : 0.01%
Valid data range : 0 to 10000
Standard setting value : 75
This parameter sets a speed zero detection signal (SSTA) detection
range.
When the motor speed is (setting data/100)% of a maximum speed or
less, the speed zero detection signal (SSTA) is set to 1.
15i 16i 30i
3025 4025 4025
Sets a torque limitation value.
Unit of data : 1%
Valid data range : 0 to 100
Standard setting value : 50
This parameter sets a torque limitation value to be applied when the
torque limitation command HIGH (TLMHA) or the torque limitation
command LOW (TLMLA) is specified.
The data indicates limitation values when the maximum torque is
100%.