B-65280EN/05 APPENDIX F.OBSERVING DATA USING THE SERVO GUIDE
- 707 -
Data type Description Description
SMERR
Positional deviation on the semi-closed loop side
(Dual position feedback function)
9D50/11 and subsequent editions
*1
NOTE
*1 Valid with 9D53 series 03 edition or later and valid with 9D70 series 02 edition or later
*2 Valid with 9D53 series 04 edition or later and valid with 9D70 series 03 edition or later
*3 To observe data marked with *1 and *2, Servo Guide Ver. 3.0 or later is needed.
F.2.2 About the Spindle Speed Control and Spindle Status Signals
As stated in the previous item, the SERVO GUIDE can be used to
observe the PMC signals (spindle speed control signals 1 and 2 and
spindle status signals 1 and 2) used by the spindle.
Listed below is the data configuration for spindle speed control signals
1 and 2 and spindle status signals 1 and 2. Refer to Chapter 3 for
explanations about each signal.
(a) Spindle speed control signal 1 (SPCT1)
#15 #14 #13 #12 #11 #10 #9 #8
RCH RSL INTG SOCN MCFN SPSL *ESP ARST
#7 #6 #5 #4 #3 #2 #1 #0
MRDY ORCM SFR SRV CTH1 CTH2 TLMH TLML
(b) Spindle speed control signal 2 (SPCT2)
#15 #14 #13 #12 #11 #10 #9 #8
DSCN SORSL MPOF
#7 #6 #5 #4 #3 #2 #1 #0
RCHHG MFNHG INCMD OVR DEFMD NRRO ROTA INDX
(c) Spindle speed control signal 3 (SPCT3)
#15 #14 #13 #12 #11 #10 #9 #8
#7 #6 #5 #4 #3 #2 #1 #0
(d) Spindle status signal 1 (SPST1)
#15 #14 #13 #12 #11 #10 #9 #8
SLVS RCFN RCHP CFIN CHP
#7 #6 #5 #4 #3 #2 #1 #0
ORAR TLM LDT2 LDT1 SAR SDT SST ALM
(e) Spindle status signal 2 (SPST2)
#15 #14 #13 #12 #11 #10 #9 #8
CSPEN
#7 #6 #5 #4 #3 #2 #1 #0
EXOF SOREN INCST PC1DT