5.FUNCTION DESCRIPTIONS FANUC AC SPINDLE MOTOR αi series B-65280EN/05
- 268 -
15
i 16i 30i
3056 4056 4056
Gear ratio (HIGH) CTH1A=0, CTH2A=0
3057 4057 4057
Gear ratio (MEDIUM HIGH) CTH1A=0, CTH2A=1
3058 4058 4058
Gear ratio (MEDIUM LOW) CTH1A=1, CTH2A=0
3059 4059 4059
Gear ratio (LOW) CTH1A=1, CTH2A=1
Unit of data : Number of motor rotations per spindle rotation / 100
(Number of motor rotations per spindle rotation / 1000 if bit 1 of
parameter No. 4006 (GRUNIT) = 1)
Valid data range : 3 to 3000
(33 to 30000 if bit 1 of parameter No. 4006 (GRUNIT) = 1)
Standard setting value : 100
NOTE
The range of gear ratios supported by this function is:
1:30 to 30:1
15
i 16i 30i
3060 4060 4060
Position gain on orientation (HIGH) CTH1A=0, CTH2A=0
3061 4061 4061
Position gain on orientation (MEDIUM HIGH) CTH1A=0, CTH2A=1
3062 4062 4062
Position gain on orientation (MEDIUM LOW) CTH1A=1, CTH2A=0
3063 4063 4063
Position gain on orientation (LOW) CTH1A=1, CTH2A=1
Unit of data : 0.01sec
-1
Valid data range : 0 to 32767
Standard setting value : 1000
These data are used to set the position gain on spindle orientation.
15
i 16i 30i
3064 4064 4064
Percentage limit to an acceleration during deceleration
Unit of data : 1%
Valid data range : 0 to 100
Standard setting value : 100
This data is used to specify the percentage limit to an acceleration
during deceleration if spindle orientation is started when the spindle
speed is lower than or equal to the limitation start seed for an
acceleration during deceleration (parameter Nos. 4326 and 4330).
Usually, specify "100".
15
i 16i 30i
3075 4075 4075
Orientation completion signal detection level (effective area for in-position
check)
Unit of data : ±1 pulse unit (360 degrees/4096)
Valid data range : 0 to 100
Standard setting value : 10
This data is used to set the detecting level of orientation completion
signal (ORARA). ORARA = 1 is satisfied if the position error is
within the setting.