B-65280EN/05 APPENDIX D.LISTS OF ALARMS/STATE ERRORS
- 685 -
Alarm No. LED display
15i 16i 30i SPM PSM
Description
SP0056 9056 SP9056 56 Internal cooling fan stopped
SP0057 9057 SP9057 57 H Converter: excessive deceleration power
SP0058 9058 SP9058 58 3 Converter: main circuit overload
SP0059 9059 SP9059 59 2 Converter: cooling fan stopped
SP0061 9061 SP9061 61
Excessive semi-closed loop/closed loop position error
alarm
SP0065 9065 SP9065 65
Abnormal travel distance in magnetic pole determination
operation
SP0066 9066 SP9066 66 Communication alarm between SPM’s
SP0067 9067 SP9067 67 Reference position return command in the EGB mode
SP0069 9069 SP9069 69 Safety speed exceeded
SP0070 9070 SP9070 70 Abnormal axis data
SP0071 9071 SP9071 71 Abnormal safety parameter
SP0072 9072 SP9072 72 Motor speed mismatch
SP0073 9073 SP9073 73 Motor sensor disconnected
SP0074 9074 SP9074 74 CPU test alarm
SP0075 9075 SP9075 75 CRC test alarm
SP0076 9076 SP9076 76 Safety function not executed
SP0077 9077 SP9077 77 Axis number mismatch
SP0078 9078 SP9078 78 Safety parameter mismatch
SP0079 9079 SP9079 79 Abnormal initial test operation
SP0080 9080 SP9080 80 Destination SPM error in inter-SPM communication
SP0081 9081 SP9081 81 Motor sensor one-rotation signal detection error
SP0082 9082 SP9082 82 Motor sensor one-rotation signal not detected
SP0083 9083 SP9083 83 Motor sensor signal error
SP0084 9084 SP9084 84 Spindle sensor disconnected
SP0085 9085 SP9085 85 Spindle sensor one-rotation signal detection error
SP0086 9086 SP9086 86 Spindle sensor one-rotation signal not detected
SP0087 9087 SP9087 87 Spindle sensor signal error
SP0088 9088 SP9088 88 Cooling fan stopped of the radiator
SP0089 9089 SP9089 89 Sub module SM (SSM) error
SP0110 9110 SP9110 b0 Communication error between amplifier modules
SP0111 9111 SP9111 b1 6 Converter: control power supply low voltage
SP0112 9112 SP9112 b2 8 Converter: excessive regenerative power
SP0113 9113 SP9113 b3 A Converter: cooling fan stopped of the radiator
SP0120 9120 SP9120 C0 Communication data alarm
SP0121 9121 SP9121 C1 Communication data alarm
SP0122 9122 SP9122 C2 Communication data alarm
SP0123 9123 SP9123 C3
Spindle switch circuit error
SP0128 9128 SP9128 C8
Excessive speed deviation alarm on spindle synchronous
control
SP0129 9129 SP9129 C9
Excessive positional deviation alarm on spindle
synchronous control
SP0130 9130 SP9130 d0 Speed polarity error in torque tandem operation