B-65280EN/05 FANUC AC SPINDLE MOTOR αi series 2.EXPLANATION OF OPERATION MODES
- 63 -
2.2.9 Details of Related Parameters
15i 16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
3003 4003 4003
DIRCT2 DIRCT1 PCMGSL
DIRCT2, DIRCT1 Setting of rotation direction at spindle orientation
DIRCT2 DIRCT1 Rotation direction at spindle orientation
0 0
By rotation direction immediately before
(It is CCW at the power on.)
0 1
By rotation direction immediately before
(It is CW at the power on.)
1 0
CCW (counterclockwise) direction looking from shaft
of motor
1 1 CW (clockwise) direction looking from shaft of motor
NOTE
When using the external one-rotation signal
(proximity switch), fix the orientation-time rotation
direction at CCW or CW for stable detection of the
one-rotation signal.
(Bits 3, 2 of No. 4003) = 1, 0 or 1, 1)
PCMGSL Selects the type of orientation.
Set this bit to 0 (orientation by a position coder).
15i 16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
3004 4004 4004
RFTYPE EXTRF
EXTRF, RFTYPE Sets the external one-rotation signal (proximity switch).
RFTYPE EXTRF External one-rotation signal (proximity switch)
0 0 None
0 1 Detects the rising edge.
1 1 Detect the falling edge.
NOTE
When using the external one-rotation signal
(proximity switch), set the type of the external
one-rotation signal (proximity switch) by using this
parameter.