11. OPTION RELATED TO SPINDLE
B–65162E/03
494
The tables below list the parameters related to spindle synchronization
control. Refer to the Parameter Manual and each CNC manual for details.
Parameter No.
FS0
–
FS15–TT
Description
1st 2nd
–
1st 2nd
Rotation direction setting
0080#6 0086#6 5820#0 4800#0
Rotational direction of spindle motor for spindle
synchronization control (1st spindle)
0080#7 0080#6 5820#1 4800#1
Rotational direction of spindle motor for spindle
synchronization control (2nd spindle)
Setting related to output signals for spindle synchronization
6533 6673 6533 3033 3173 4033
Target level for the spindle speed synchronization
control
0303 0303 5810 4810
Difference between error pulses for the two
spindles, regarded as spindle phase synchroniza-
tion completion signal
0576 0576 5811 4811
Difference between error pulses for the two
spindles, regarded as an alarm during spindle syn-
chronization control
Setting of gear ratio data between the spindle and motor
6506#1 6646#1 6506#1 3006#1 3146#1 4006#1 Increment system for gear ratios
6556 to
6559
6696 to
6699
6556 to
6559
3056 to
3059
3196 to
3199
4056 to
4059
Gear ratio between the spindle and motor
(selected by DI signals CTH1A and CTH2A from
the PMC)
Setting related to a shift amount and phase synchronization
6534 6674 6534 3034 3174 4034 Shift for spindle phase synchronization control
6535 6675 6535 3035 3175 4035
Compensation data for spindle phase synchro-
nization control
6506#3 6646#3 6506#3 3006#3 3146#3 4006#3
Setting to disable automatic one–rotation signal
detection when the spindle synchronization mode
is switched
Position gain setting
6565 to
6568
6705 to
6708
6565 to
6568
3065 to
3068
3205 to
3208
4065 to
4068
Position gain for spindle synchronization control
(The same value must be set for both spindles.)
(selected by DI signals CTH1A and CTH2A from
the PMC)
Setting of acceleration/deceleration time constants
6532 6672 6532 3032 3172 4032
Acceleration/deceleration time constant for spindle
synchronization control
(The same value must be set for the 1st and 2nd
spindles.)
11.4.6
Parameters