5. DIGITAL INPUT/OUTPUT MODULES CONNECTIONS B-61813E/03
−56−
(26) Output module AOR16G
Item Specifications
Points/module 16 points
Points/common 4 points/common
Maximum load 30VDC/250VAC, 2A (resistance load)
Minimum load 5VDC, 10mA
Maximum current 4A/common
Limit of load Refer to load derating curve (Fig. 5.3 (e))
OFF→ON
Max.15msResponse
time
ON→OFF
Max.15ms
This is the value from input to output in the module. The actual value is
determined by adding it to the scanning time depending on each
system.
Output display LED display
External connection Terminal block connector (20 terminals, M3.5 screw terminal)
Mechanical Min. 20,000,000 timesRelay life
Electrical Min. 100,000 times (resistance load)
Terminal connection and
circuitry
V : Direct current power or alternating current power