B–62075E/04
3. INPUT AND OUTPUT OF DATA
197
Parameter setting procedure
1 Enable parameter writing.
(1)Set the MDI mode or emergency stop state.
(2)When the MDI mode is selected instead of the emergency stop
state, switch memory protection key KEY2 to ON.
(3)Display the general setting screen.
1) Press the
SETTING
key.
2) Press the
function menu key.
3) Press the [CHAPTER] soft key.
4) Press the [GENERAL] soft key.
The general setting screen can also be displayed by pressing the
SETTING
key several times.
(4)Set bit 0 of setting data No. 8000 to 1.
1) Key in 8000, then press the [INP–NO.] soft key.
2) Press
1
and
INPUT
INSERT
.
Then, the “SW000 parameter write switch on” alarm is issued.
2 Display the parameter screen.
(1)Press the
SERVICE
key.
(2)Press the
function menu key.
(3)Press the [CHAPTER] soft key.
(4)Press the [PARAM] soft key.
The parameter screen can also be displayed by pressing the
SERVICE
key
several times.
3 Set parameters.
Press the operation menu key. Then, the operation menu shown below
appears in the soft key menu field.
(1)INP–NO.: Searches for a parameter number.
Example:
Parameter number
→INP–NO.
(2)ON : 1: Sets the value where the cursor is positioned to 1
(only for bit parameter).
(3)OFF : 0: Sets the value where the cursor is positioned to 0
(only for bit parameters).
3.1
SETTING THE
PARAMETERS
REQUIRED FOR
INPUT/OUTPUT