APPENDIX
B–62075E/04
C. ERROR CODE TABLE
374
Number Message displayed on CRT Contents Remarks
SR 160 INTERNAL DATA OVER
FLOW
Coordinates specified in an absolute or machine coordinate sys-
tem are out of range.
In general, this alarm is generated when the rotational axis is ro-
tated a number of times and an absolute coordinate becomes
greater than +99999.999 or less than –99999.999 (for increment
system IS–B).
Perform reference position return when this alarm occurs.
SR 310 H, S, C ERROR G10.3, G11.3, or G65.3 is used incorrectly.
SR 311 H, S, C ERROR A command not permitted during high–speed machining was spe-
cified.
SR 312 H, S, C ERROR Address P, Q, or L is out of range.
SR 313 H, S, C ERROR High–speed machining data does not exist for the number that
was called.
SR 314 H, S, C ERROR No cluster exists for the number that was called.
SR 315 H, S, C ERROR An attempt was made to register a number for which high–speed
machining data already exists.
SR 316 H, S, C ERROR Memory is full.
SR 317 H, S, C ERROR The maximum number of sets of high–speed machining data has
been registered (no additional high–speed machining data can be
registered).
SR 318 H, S, C ERROR An attempt was made to register high–speed machining data dur-
ing background editing.
SR 319 H, S, C ERROR There is an error in the format of high–speed machining data.
SR 320 H, S, C ERROR A macro interrupt occurred during high–speed machining.
SR 424 OVER MAXIMAM TOOL
DATA
An attempt was made to register new tool data even though the
maximum number of sets of tool data has already been set (tool
No. specified for tool offset).
SR 590 TH ERROR TH alarm (A character with a parity error was entered in a signifi-
cant data area.)
SR 591 TV ERROR TV alarm (The number of characters in a block was not even.)
SR 592 END OF RECORD EOR (End of Record) was specified partway through a block.
SR 600 PARAMETER OF RESTART
ERROR
There is an error in the specification of the program restart param-
eter.
SR 805 ILLEGAL COMMAND An attempt was made to use an illegal command for the reader/
punch interface. This is generally a system error.
SR 806 DEVICE TYPE MISS
MATCH
An attempt was made to use a command which is invalid for the
currently selected I/O device. For example, this alarm occurs
when an attempt is made to perform a file head search even
though the medium is not a FANUC floppy disk.
SR 807 PARAMETER SETTING ER-
ROR
An I/O interface which was not selected as an option was speci-
fied, or the settings or parameters related to the I/O interface are
set incorrectly.
SR 810 PTR NOT READY The ready signal for the tape reader is off.
SR 812 OVERRUN ERROR (PTR) The next character was received by the tape reader before it could
read a previously received character.
SR 820 DR OFF(1) The data set ready signal for reader/punch interface 1 went off.
SR 821 CD OFF(1) The signal quality detection signal for reader/punch interface 1
went off.
SR 822 OVERRUN ERROR(1) The next character was received by reader/punch interface 1 be-
fore it could read a previously received character.
SR 823 FRAMING ERROR(1) No stop bit was detected for a character received by reader/punch
interface 1.