B–62075E/04
1. OPERATION OF MDI PANEL
44
(c) History data items are output in ASCII code in the following
format.
(i) MDI key
Example When the [A] key is pressed
[MDI] key pushed A LF
(ii) DI/DO
Example1 When the state of G003.5 changes from off to on
DI/DO changed G3.5_ON LF
Example2 When different signals with the same address are
changed at the same time
DI/DO changed F0.6_ONF0.1_OFF LF
(iii) Alarm
Example When the alarm, ”PW000 TURN OFF THE
POWER” occurs
Alarm! PW0 at ’92/8/30 23:17:56 LF
(iv) Time
Example1 At 23:17:56 on August 30, 1996
’96/8/30 23:17:56 LF
Example2 When the power is turned on
’96/8/30 23:17:56 Power On LF
(d)Communication protocol
Refer to the case where the NC sends data in “Transmission
Method for the RS–232–C Interface” in the FANUC Series 15–B
Operator’s Manual (Operation).
(5)Erasing history data
(a) Press the [OPE_HIS] soft key (one of the chapter selection keys).
(b)Press the [ERASE] soft key (one of the operation selection keys).
(c) Press the [EXEC] soft key (one of the operation instruction keys).
When the [EXEC] soft key is pressed by mistake during selection,
press the [CANCEL] soft key.
When operation history data is erased, the date and time it was
erased is recorded at the beginning of new history data.
Select the [DIDO SELECT] key. Then, the DI/DO SELECT screen is
displayed.
MDI * * * STOP * * * * * * * * * * 00:00:00 * * *
CLEAR ALL_CLR ON:1 OFF:0 CHAPTER +
DI/DO SELECT O0001 N0001
NO. ADDRESS SIGNAL NO. ADDRESS SIGNAL
01 X000 00001000 11 G000 00000001
02 X004 10000000 12 G004 00000010
03 X008 00001100 13 G008 00000011
04 X009 00111000 14 G003 01011100
05 X012 00001111 15 G043 00100001
06 Y000 01000000 16 F000 01100010
07 Y004 00110000 17 ********
08 Y007 00011100 18 ********
09 Y008 00011100 19 ********
10 Y010 00011100 20 F020 10101010
1.10.3
Select DI/DO Screen