B–62075E/04
1. OPERATION OF MDI PANEL
45
Specifying data
1. Press the cursor keys or to move the cursor to the position
to enter data.
2. Enter a signal type (X, Y, G, or F) and address, then press the [INPUT]
soft key.
Example Y4([INPUT] key)
Valid data range: G0 to G511, F0 to F319, X0 to X127, or Y0 to Y127
3. Specify signal address Y004 in the ADDRESS column, then set the
SIGNAL column to the initial value (00000000).
4. The operation selection keys have the following functions:
(i) CLEAR
When the [CLEAR] soft key and the [EXEC] soft key are
pressed, the signal data at the cursor is deleted. The contents of
the signal field is changed to ********, and the address field is
cleared. When the [CLEAR] soft key is pressed by mistake, press
the [CANCEL] key.
(ii) ALL_CLR
When the [ALL_CLR] soft key and the [EXEC] soft key are
pressed, all specified data items are deleted. When the
[ALL_CLR] soft key is pressed by mistake, press the [CANCEL]
key.
(iii) ON:1
Press this soft key to set all bits of the data item at the cursor to 1.
(iv) OFF:0
Press this soft key to set all bits of the data item at the cursor to 0.
(v) INPUT
This soft key is used to enter a signal address. It is also used to
enter the value of the signal after a signal address is entered.
NOTE
Changes in signals cannot be deleted unless they continue
for longer than 16ms.
Parameter No. 0013#5: Specifies whether to display DI/DO
history information.
Parameter No. 0013#4: Specifies whether to display MDI key
operation history information.
Parameter No. 0015#4: Specifies whether to display the
deletion key.
Parameter No. 0015#3: Specifies whether to display the
OPERATION HISTORY screen.
1.10.4
Related Parameters