B–62075E/04
3. INPUT AND OUTPUT OF DATA
220
7 Select memory (automatic operation) mode, then press the cycle start
button to start automatic operation.
The program runs, and the tool offset data is set.
8 Upon the completion of the operation, display the tool offset value
screen.
9 By switching between pages with the page keys
and , check
that the tool offset data has been entered correctly.
10 Select edit mode.
11 Display the program contents screen.
12 Delete the program registered for tool offset data input.
Enter
O
?
Program Number
DELETE
to delete the program.
1 Check and set the following parameters as required.
#7
0011
#6 #5 #4 #3 #2 #1 #0
NE8
NE8 Specifies whether the editing of programs O8000 to O8999 is to be
enabled or disabled.
0 : Enabled
1 : Disabled
#7
2200
#6 #5 #4
NM9
#3
NPE
#2 #1 #0
NPE Specifies whether M02, M30, and M99 are to be regarded as program end
codes in program registration.
0 : Regarded as program end codes
1 : Not regarded as program end codes
NM9 Specifies whether M99 is to be regarded as a program end code in program
registration.
0 : Regarded as a program end code
1 : Not regarded as a program end code
#7
2201
#6 #5 #4 #3 #2 #1
ND9
#0
ND9 Specifies whether the editing of programs O9000 to O9999 is to be
enabled or disabled.
0 : Enabled
1 : Disabled
2 Select edit mode.
3 Set memory protection key KEY3 to ON (KEY3 = 1).
4 Prepare a program for part program input on the I/O device side.
3.2.3.7
Part program registration