B–62075E/04
1. OPERATION OF MDI PANEL
41
This function always collects history data for keys pressed by the NC
operator and the states of signals set by the NC operator. In addition, this
function enables the operator to monitor history data when necessary.
Press the [HISTRY] soft key. Then, the OPERATION HISTORY screen
is displayed. Smaller numbers represent older data.
MDI***STOP**** *** *** 00:00:00 ***
PUNCHSEARCHLASTTOP CHAP-
TER
OPERATION HISTORY O0001 N00001
NO. DATA NO. DATA NO. DATA NO. DATA
01 PW 000 11 5 21 G003.3↓ 31 G
02 96/08/25 12 [SOFT 5] 22 G003.4↑ 32 9
03 08:40:00 13 1 23 [SOFT 2] 33 0
04 <RESET> 14 0 24 O 34 X
05 G003.5↓ 15 0 25 0 35 4
06 G003.3↑ 16 0 26 0 36 5
07 [SOFT 6] 17 [SOFT 1] 27 0 37 6
08 2 18 <RESET> 28 1 38 .
09 2 19 96/08/25 29 [SOFT 2] 39 F
10 0 20 08:41:36 30 ; 40 1
(1)TOP
Displays the first page of history data, which starts with oldest history
data item.
(2)LAST
Displays the last page of history data, which ends with the newest
history data item.
(3)SEARCH
By selecting the SEARCH key from the operation selection keys, the
search operation described below can be performed.
(a) Signal data item
(i) Press the [DIDO] key.
(ii) Use one of the following search methods:
1. Enter a signal type (X, Y, G, or F), address, decimal point
(.), and bit number.
ExampleG3.5
When the entered signal type, address, and bit number
agree with those of a history data item, that history data
item is found.
2. Enter a signal type (X, Y, G, or F) and address.
ExampleG3
When the entered signal type and address agree with those
of a history data item, that history data item is found.
3. Enter a signal type (X, Y, G, or F).
ExampleG
When the entered signal type agrees with that of a history
data item, that history data item is found.
1.10
OPERATION
HISTORY
1.10.1
Display Method
1.10.2