B–62075E/04
1. OPERATION OF MDI PANEL
46
Classifi-
cation
Function
Data
protecion
key
PWE =1
(DATA
No. 8000)
Mode
selection
Function
key
Clear Tool offset Value KEY 1 Power
ON
OFFSET
Operation menu key → [ALL–CLR] → [ALL], [WEAR],
or [GEOMETRY]
Data In-
put From
Tape
One Program Input
(program number
not changed)
KEY 3 EDIT PRGRM
Operation menu key → [READ] → [1–PRGRM] →
[NEW]
One Program Input
(program number
changed or added)
KEY 3 EDIT PRGRM
Operation menu key → [READ] → [(PROG#)] →
Program number → [EXEC]
Add Program KEY 3 EDIT PRGRM
Operation menu key → [READ] → [1–PRGRM] ]→
[ADD]
Registration of all
programs
KEY 3 EDIT PRGRM
Operation menu key → [READ] → [ALL]
Pitch Error Com-
pensation amount
f Emergen-
cy
SW. ON.
SERVICE
[PITCHH] → [READ]
Data In-
put From
MDI
Parameter f MDI or
Emergen-
cy switch
ON.
SERVICE
[ON:1]
[PARAM] → [INP–No.] → [OFF:0]
Data No. → [EXEC] → [INPUT]
[+INPUT]
Offset Value KEY 1 OFFSET
Operation menu key →
[INPUT] (Absolute input)
[+INPUT] (Incremental input)
→ Offset value → [EXEC]
Setting Data KEY 2 MDI SETTING
Operation menu key →
[HANDY] (Setting relating to I/O)
[GENERAL] (Settable parameter)
→
[1 : ON]
[0 : OFF] → Data → [EXEC]
[(VALUE)]
1.11