4. INTERFACE BETWEEN NC AND PMC
248
(1)Nonvolatile memory control
#7
K016
#6 #5 #4 #3 #2 #1 #0
#7 (MWRTF2) Writing status in nonvolatile memory
#6 (MWRTF1) Writing status in nonvolatile memory
(2)PMC system parameter
The following keep relays are used by the system, therefore they
cannot be used in the sequence program.
#7
K017
#6 #5 #4 #3 #2 #1 #0
#6 ANASTAT 0 : Pressing [EXEC] key initiates sampling by signal waveform display
function.
1 : Turning power to on initiates sampling by signal waveform display
function.
#5 TRCSTAT 0 : Signal tracing starts by soft key [EXEC] in signal trace function.
1 : Signal tracing starts automatically by power on in signal trace
function.
#4 MEMINP 0 : Data input cannot be done in memory contents display function.
1 : Data input can be done in memory contents display function.
#2 AUTORUN 0 : A sequence program is executed automatically after the power is
turned on.
1 : A sequence program is executed by sequence program soft key.
#1 PRGRAM 0 : Built–in programmer is not used.
1 : Built–in programmer is used.
#0 LADMASK 0 : Dynamic display of ladder is executed.
1 : Dynamic display of ladder is not executed.
#7
K018
#6 #5 #4 #3 #2 #1 #0
#7 IGNDINT 0 : When the screen is switched to the PCMMDI screen, the CRT is
initialized.
1 : When the screen is switched to the PCMMDI screen, the CRT is not
initialized.
* This flag is used to control whether the PMC management software
initializes the CRT when switching to the PMCMDI screen from
another screen is performed. When this flag is set to on, the CRT must
be initialized using the application.
#3 TRNSRAM 0 : A ladder program is not automatically sent to the backup RAM after
on–line editing is completed.
1 : A ladder program is automatically sent to the backup RAM after
on–line editing is completed.
#2 TRGSTAT 0 : The trigger stop function does not automatically start when the power
is turned on.
1 : The trigger stop function automatically starts when the power is
turned on.
D PMC–NB