B–62075E/04
1. OPERATION OF MDI PANEL
21
#10 Other than the above(Note3)
#11 Not used.
NOTE
1 The DO DEN or IPEN signal is high.
Constant surface speed control is being executed.
The status of the DI HEAD1/2 signal is invalid in the MDI
mode. (Only for the Series 15–TT)
2 The DO OP signal is low for return operation.
The DI MLK signal is on.
The DO STL signal is on.
3 The system enters the start lock state during tracing.
A tool is being retracted in the hobbing machine.
On the bed grinder, an alarm is issued or the DI MLK signal
is on.
The axis to be retracted in the jog mode is at a position at
which starting is disabled.
The type of the alarm issued is displayed.
When the alarm status is released, the corresponding bit is set to 0.
#15
1007
#14 #13 #12 #11 #10 #9 #8
#7
1008
#6 #5 #4 #3 #2 #1 #0
Each bit indicates an alarm type when 1 is displayed for the bit as follows:
#0 Background P/S alarm
#1 Foreground P/S alarm
#2 Overheating
#3 Sub–CPU error
#4 Excessive synchronous error
#5 Parameter writing switch on
#6 Overtravel/external data input/output error
#7 PMC error
#8 External alarm message
#9 Not used.
#10 Serious P/S
#11 Not used.
#12 Servo alarm
#13 I/O error
#14 Input of a parameter requiring power disconnection
#15 System error
D Displaying the type of an
alarm