B–62075E/04
1. OPERATION OF MDI PANEL
31
0 : Starts sampling data the moment the [TRACE] key is pressed.
1 : Starts sampling data when the trigger signal rises after the
[TRACE] key is pressed.
2 : Starts sampling data when the trigger signal falls after the
[TRACE] key is pressed.
NOTE
When no trigger signal is specified, 1 and 2 are assumed to
be 0.
(b)TRIGGER
Enter the PMC address and bit number corresponding to a trigger
signal in the TRIGGER field on the WAVE DIAGNOSIS
(PARAMETER) screen.
Valid data range : G000.0 to G511.7, F000.0 to F319.7,
Y000.0 to Y127.7, and X000.0 to X127.7
(c) TIME RANGE
Enter 25, 50, 100, 200, 400, or 800 in the TIME RANGE field on
the WAVE DIAGNOSIS (PARAMETER) screen. The sampling
time is specified as 0.5, 1.0, 2.0, 4.0, 8.0, or 16.0 s.
The sampling time determines not only sampling conditions, but
also graph display conditions.
(d)DATA KIND
Select the type of waveform to be traced and enter your choice in
the DATA TYPE field on the WAVE DIAGNOSIS
(PARAMETER) screen.
0 : Servo error (pulses, detection units)
1 : Number of servo pulses to be generated
(pulses, command units)
2 : Servo torque (%)
5 : Actual speed (pulses, detection units)
6 : Value of the electric current command for the servo
(%)
7 : Data during heat simulation (%)
9 : Composite speed for all axes (mm/min or rpm)
10: Spindle speed (rpm)
11: Load meter for a spindle (%)
NOTE
The servo torque and the value of the electric current
command are represented as percentages of the
corresponding settings in parameter 1979. Spindle speed
refers to the speed of a digital spindle only.