B–62075E/04
3. INPUT AND OUTPUT OF DATA
222
Conversational data is read from an external storage device (reader), or
punched out to an external storage device (punch). For conversational
data input/output, the data input/output screen shown below, which is an
auxiliary screen, is used.
DATA INPUT/OUTPUT O1000 N01000
1) PARAMETER : P–9999
2) TOOL FILE : T–9999
3) CUTTING CONDITION FILE : F–9999
4) PRE–TOOL LIST : R–9999
5) PASCAL : S–9999
6) CONVERSATIONAL DATA : M–9999
7) PROGRAM
1 PROGRAM : 0????
ALL PROGRAM : 0–9999
: 0 ????,0 ????
>
READ PUNCH
OR
READ
PUNCH
DATA
1
No.
0060
As shown on the above screen, conversational data can be read or punched
by entering necessary address and program number information and
pressing the respective soft key. The procedure is described below.
1. Set a data input/output parameter.
D Press conversational function key
SETTING
to display the setting
screen.
D Set a parameter required for data input/output. In the parameter, set
the same data as that of the NC parameter having the same number.
2. For program input, release the memory protection set using protection
key KEY3.
3. For parameter input, enable parameter setting by NC mode setting
(PWE = 1).
4. Mount the floppy disk containing the data to be entered.
5. Display the data input/output screen.
3.2.4
15–MFB Data
Input/Output
3.2.4.1
Conversational data
input/output
3.2.4.2
Conversational data
input