B–62075E/04
1. OPERATION OF MDI PANEL
25
If an alarm is detected at power–on when the absolute position is detected
optionally, the message SV101 DATA ERROR (ABS PCDR) or OT032
NEED ZRN (ABS PCDR) appears. The cause of the alarm is indicated
in the diagnostic data.
If the alarm message SV101 DATA ERROR (ABS PCDR) or OT032
NEED ZRN (ABS PCDR) appears on the screen, the cause of the alarm
is indicated in the diagnostic data. The number of the diagnostic data is
3018 for axis 1, 3038 for axis 2, 3058 for axis 3, and the start number +
8 for other axes.
#7
APMVAL3028
#6
APPER
#5
APFER
#4
APTER
#3
APCER
#2
APBATZ
#1
APPLSM
#0
APNZRN
Symbol Description (Action to be taken)
APNZRN Absolute–position detection is not correlated with the reference
position.
(Action: Correlate absolute–position detection with the reference
position.)
APPLSM A pulse error alarm occurred.
(Action: Correlate the absolute–position detection with the refer-
ence position.)
APBATZ The voltage of the battery of the absolute pulse coder is 0.
(Action: Replace the battery and correlate absolute–position
detection with the reference position.)
APCER A communication error occurred during data transmission.
(Action: Replace the pulse coder.)
APTER A time–out error occurred during data transmission.
(Action: Replace the pulse coder.)
APFER A framing error occurred during data transmission.
(Action: Replace the pulse coder.)
APPER A parity error occurred during data transmission.
(Action: Replace the pulse coder.)
APMVAL An excessive motor displacement alarm occurred.
This alarm occurs if the machine moves by more than 24,000
pulses in the detection unit at power–on.
(Action: Take appropriate action for the machine so that it does
not move at power–on.)
Diagnosis
No.
Description
4100 Amount of shift in the coordinate system by manual operation
4101 Amount of shift in the coordinate system by a manual interrupt
using a function such as the simultaneous automatic/manual
function
4102 Amount of offset in the coordinate system by workpiece coordi-
nate system setting using the G92 command
4103 Amount of offset in the coordinate system by local coordinate
system setting using the G52 command
4104 Amount of shift in the coordinate system in the machine lock
state
D Checking an
absolute–position
detection alarm