B–62075E/04
1. OPERATION OF MDI PANEL
19
(1)Press the
SERVICE
key.
(2)Press the [DIAGNOS] soft key. Then, the diagnosis screen is
displayed.
The status of the interface signals (F and G) between the PMC and CNC
can be displayed as the CNC internal status. The following table lists the
correspondence between the numbers of this diagnostic data and address
numbers (F000 and after and G000 and after) .
Output from the CNC
(G000 and after)
Input to the CNC
(F000 and after)
For the BMI interface Diagnostic numbers 0
and after
Diagnostic numbers 200
and after
For the FS3/6 inter-
face
Diagnostic numbers 400
and after
Diagnostic numbers 500
and after
For example, data passed to the PMC through address G010 by the CNC
is displayed as diagnostic data with number 10 (for the BMI interface) or
number 410 (for the FS3/6 interface). For the interface signals, see
Sec.4.5.
For details of each signal, refer to the corresponding interface connection
manual.
1.5
DIAGNOSIS
FUNCTION
1.5.1
Displaying the
Diagnosis Screen
1.5.2
Displaying the Status
when it Appears that a
Command is not being
Executed
D Displaying the status of
the PMC interface
signals