B–62075E/04
3. INPUT AND OUTPUT OF DATA
207
5112 Baud rate of reader/punch unit corresponding to device number 1
[Setting input]
[Data type] Byte
[Valid data range] 1 to 12
Set the baud rate of the reader/punch unit corresponding to device number
1.
The table below gives the correspondence between the specified numbers
and baud rate.
Specified number Baud rate Specified number Baud rate
1
2
3
4
5
6
50
100
110
150
200
300
7
8
9
10
11
12
600
1200
2400
4800
9600
19200
5120 Code number of reader/punch unit corresponding to device number 2
5121 Number of stop bits of reader/punch unit corresponding to device number 2
5122 Baud rate of reader/punch unit corresponding to device number 2
5130 Code number of reader/punch unit corresponding to device number 3
5131 Number of stop bits of reader/punch unit corresponding to device number 3
5132 Baud rate of reader/punch unit corresponding to device number 3
5140 Code number of reader/punch unit corresponding to device number 4
5141 Number of stop bits of reader/punch unit corresponding to device number 4
5142 Baud rate of reader/punch unit corresponding to device number 4
5150 Code number of reader/punch unit corresponding to device number 5
5151 Number of stop bits of reader/punch unit corresponding to device number 5
5152 Baud rate of reader/punch unit corresponding to device number 5
5160 Code number of reader/punch unit corresponding to device number 6
5161 Number of stop bits of reader/punch unit corresponding to device number 6
5162 Baud rate of reader/punch unit corresponding to device number 6
The method for setting these parameters is the same as for setting the
specifications of the input/output unit corresponding to device number 1.