B–62075E/04
3. INPUT AND OUTPUT OF DATA
212
(12) Press the [FDCAS] soft key to select the FANUC Floppy Cassette
as the I/O device.
(13) Press the [PCPRM] soft key to select PMC data as the data type.
(14) Press the [WRITE] soft key to select data output.
(15) Enter a desired file name from the keyboard, then press the [EXEC]
key.
Example: “@ABC” [EXEC] key
Channel 1: JD5A, Channel 2: JD5B
Specify a desired value on the screen, displayed by pressing the [SPEED]
key on the I/O screen.
1 Display the pitch error screen.
1) Press the
SERVICE
key.
2) Press the
function menu key.
3) Press the [CHAPTER] soft key.
4) Press the [PITCH] soft key.
The pitch error screen can also be displayed by pressing the
SERVICE
key
several times.
2 Press the
operation menu key to display [PUNCH] in the soft key
menu.
3 Press the [PUNCH] soft key. Then, the soft key menu changes again
to display the [PITCH] soft key.
4 Press the [PITCH] soft key to start pitch error compensation data
output.
1 Display the custom macro variable screen.
1) Press the
SETTING
key.
2) Press the function menu key.
3) Press the [CHAPTER] soft key.
4) Press the [MACRO] soft key.
The custom macro variable screen can also be displayed by pressing
the
SETTING
key several times.
2 Press the operation menu key to display [PUNCH] in the soft key
menu.
3 Press the [PUNCH] soft key. Then, the soft key menu changes again
to display the [COMMON VARIABLE 2] soft key.
4 Press the [COMMON VARIABLE 2] soft key to start custom macro
variable value output.
D Channel number
D Transfer speed
modification
3.2.2.3
Pitch error
compensation data
output
3.2.2.4
Custom macro variable
value output