B–62075E/04
5. TROUBLESHOOTING
278
(i) Check the value of the parameter using the parameter list.
1825 Servo loop gain for each axis (Standard value: 3000)
(ii) The servo system may be erroneous. Investigate the servo
system according to the description of servo alarms SV023,
SV008, and SV009.
b. The manual feedrate override is 0%.
Check the signals by using the PMC diagnostic function (PMC
DGN).
#7
*JV15G014
#6
*JV14
#5
*JV13
#4
*JV12
#3
*JV11
#2
*JV10
#1
*JV9
#0
*JV8
(M/T series)
#7
*JV7G015
#6
+JV6
#5
*JV5
#4
*JV4
#3
*JV3
#2
*JV2
#1
*JV1
#0
*JV0
(M/T series)
#7
*JV15G104
#6
*JV14
#5
*JV13
#4
*JV12
#3
*JV11
#2
*JV10
#1
*JV9
#0
*JV8
(TT series)
#7
*JV7G105
#6
+JV6
#5
*JV5
#4
*JV4
#3
*JV3
#2
*JV2
#1
*JV1
#0
*JV0
(TT series)
When the override is 0%, the bits of the above addresses are set to
all 1 or all 0.
c. An interlock/start lock signal is being input.
Check the signal by using the PMC diagnostic function (PMC
DGN).
(i) The interlock signal (*IT) is being input.
#7
G000
#6 #5 #4 #3 #2 #1 #0
*IT
(M/T series)
#7
G096
#6 #5 #4 #3 #2 #1 #0
*IT
(TT series)
0 in the *IT bit indicates that the interlock signal is being
input.
(ii) An axis interlock signal (*ITn), servo off signal (*SVFn), or
controlled axis detachment signal (DTCHn) is being input.
#7
DTCH1G064
#6
*SVF1
#5 #4
*IT1
#3 #2 #1 #0
(M/T series
first axis)
#7
DTCH1G128
#6
*SVF1
#5 #4
*IT1
#3 #2 #1 #0
(TT series
first axis)
The address for the nth axis is as follows:
M/T series: 64 + (n – 1)*4
TT series: 128 + (n – 1)*4
0 in the *ITn or *SVFn bit or 1 in the DTCHn bit indicates that
the corresponding signal is being input.