B–62075E/04
4. INTERFACE BETWEEN NC AND PMC
240
Soft key [STOP]
Pressing the [STOP] key stops tracing. The trace results are
maintained.
(3)Displaying the trace results
The latest trace result is indicated by the cursor. The cursor moves on
the CRT screen as the trace results are updated.
If the cursor moves off the screen, the latest trace result can be
displayed by scrolling the screen using the
cursor key.
1. Trace parameter screen
PMC SIGNAL TRACE
T.DISP
EXEC
MONIT RUN
Changes to a trace memory display screen (Screen on
the next page)
TRACE MODE :
(0:1BYTE/1:2BYTE/2:WORD)
1STTRACE ADDRESS CONDITION
ADDRESS TYPE : (0:PMC/1:PHY)
ADDRESS :
MASK DATA :
2NDTRACE ADDRESS CONDITION
ADDRESS TYPE : (0:PMC/1:PHY)
ADDRESS :
MASK DATA :
Select each item by cursor key
a. TRACE MODE: Select the trace mode
0=Records changes of 1–byte signals
1=Records changes of independent 2–byte signals
2=Records changes of consecutive 2–byte signals
b. ADDRESS TYPE:
0=PMC address is used for tracing address.
1=Physical address is used for tracing address.
(Mainly used for C–language program)
c. ADDRESS:Set a tracing address.
D PMC–NB