6.3 PARAMETERS
The following describes the parameters related to the data server
functions.
Parameters
0020 Interface number of input device for foreground
[Input section] Setting input
[Data type] Integer
[Valid data range] 0 to 16
14: Selects the data server for the input device.
0021 Interface number of output device for foreground
[Input section] Setting input
[Data type] Integer
[Valid data range] 0 to 16
14: Selects the data server for the output device.
0022 Interface number of input device for background
[Input section] Setting input
[Data type] Integer
[Valid data range] 0 to 16
14: Selects the data server for the input device.
0023 Interface number of output device for background
[Input section] Setting input
[Data type] Integer
[Valid data range] 0 to 16
14: Selects the data server for the output device.
5028 Selects host 1 OS.
[Input section] Parameter input
[Data type] Integer
[Valid data range] 0 and 1
1: UNIX/VMS.
0: Windows 95/98/NT.
5029 Selects host 2 OS.
[Input section] Parameter input
[Data type] Integer
[Valid data range] 0 and 1
1: UNIX/VMS.
0: Windows 95/98/NT.