B-63354EN/04 III. SETTING 1.FACTOLINK FUNCTIONS FOR THE 16i/18i/21i
- -25
Display items and setting items
Display items related to Ethernet functions
Those items related to Ethernet functions are displayed.
Item Description
MAC ADDRESS MAC address of the Ethernet board
NUMBER OF
SCREENS
Total number of Ethernet error message screens used
by the Ethernet functions
MAXIMUM PATH Number of control systems in the CNC
HDD EXISTENCE Indicates whether a hard disk or ATA flash card is
mounted on the Ethernet board.
0: Not mounted.
2: Mounted.
TCP/IP setting items for the CNC
Set the TCP/IP items for the CNC.
Item Description
IP ADDRESS Specifies the IP address of the CNC.
(Format: "192.168.0.1")
SUBNET MASK Specifies the mask address of the network IP address.
(Format: "255.255.255.0")
ROUTER IP
ADDRESS
Specifies the router IP address.
Specify this address when the network incorporates a
router.
(Format: "192.168.0.99")
FACTOLINK setting items
Set the items related to the host computer on which the FACTOLINK
server runs.
Item Description
IP ADDRESS 1 Specifies the IP address of the personal computer to be
accessed by the FACTOLINK functions.
(Format: "192.168.0.101")
PORT NUMBER 1 Specifies the port No. to be used by the FACTOLINK
functions within a range of 5001 to 65535.
This port No. must match "ocsnc" in the personal
computer's "services" file.
For details of how to set this, refer to the " FACTOLINK
Script Function, OPERATOR'S MANUAL (B-
75054EN)."
IP ADDRESS 2 Specifies the IP address of the personal computer to be
accessed by the FACTOLINK functions.
(Format: "192.168.0.102")
PORT NUMBER 2 Specifies the port No. to be used by the FACTOLINK
functions within a range of 5001 to 65535.
This port No. must match "ocsnc" in the personal
computer's "services" file.
For details of how to set this, refer to the "FANUC
FACTOLINK Script Function, OPERATOR'S MANUAL
(B-75054EN)."