EDIT.
SHEET
DRAW. NO.
CUST.
TITLE
15
93
DESCRIPTIONDESIG.DATE
Power Failure Backup Module
Descriptions
A-53866E-464
(3) Energy supply capability in the event of a power failure: Depends on the input power
voltage of the PSM and the number of sub modules C connected.
Energy amount per one sub module C
A06B-6077-H010 (for 200V) A06B-6083-H245 (for400V)
PSM input voltage
V1
Energy amount
W1
PSM input voltage
V1
Energy amount
W1
AC170V 478J AC340V 330J
AC200V 755J AC400V 530J
240 VAC 1195J AC480V 850J
Up to eight sub modules C can be connected. For selection information, see Section
8.2.
(4) Maximum regeneration capability (resistor regeneration): Depends on the type of sub
module R and the number of sub modules R connected.
200V input type
Type of sub module R
No. of sub
modules R
connected
Regeneration
capability <1>
Regeneration
capability <2>
Remarks
A06B-6089-H712 1 20kW 100kJ
A06B-6089-H712 2 40kW 200kJ Parallel
connection
A06B-6077-H020 1 40kW 80kJ
* The upper limit on the number of sub modules that can be connected is 2 for
the A06B-6089-H712 and 1 for the A06B-6077-H020.
400V input type
Type of sub module R
No. of sub
modules R
connected
Regeneration
capability <1>
Regeneration
capability <2>
Remarks
A06B-6077-H020 1 40kW 80kJ
* The upper limit on the number of sub modules that can be connected is 1.
Regeneration capability <1>: Maximum output of the motor that can be decelerated
in the event of a power failure
Regeneration capability <2>: Product of the motor output [kW] during deceleration
and the deceleration time [sec]
For information on selecting sub module R, see Section 8.1.