EDIT.
SHEET
DRAW. NO.
CUST.
TITLE
39
93
DESCRIPTIONDESIG.DATE
Power Failure Backup Module
Descriptions
A-53866E-464
(13) Details of the connection of cable K75
This cable is used to supply the control power (24 VDC) for the power failure backup
module from the αi/αHVi amplifier.
XMIFA (B4)
*ESP (A4)
BATL (B3)
MIFA (A3)
0V (B2)
0V (A2)
24V (B1)
24V (A1)
K75
CXA2A
(2) 0V
(1)24V
CX14
SVM or SPM Power failure backup module
Connector specifications
CXA2B CX14
Manufacturer Tyco Electronics AMP
Connector type D-2100 series
Housing 1-1318119-4
Contact 1318107-1
D-3100 series
Housing 1-178288-3
Contact 1-175218-1
Wire size 0.5mm
2
,
AWG20
Insulated coating dimension 1.08-2.83 mm
(14) Details of the connection of cable K77
This cable is used to detect a power failure. It is used with the power failure backup
module A06B-6091-H002.
Cable type: Vinyl cabtyre cable, JIS C 3312, 3-conductor
Conductor: 1.25mm
2
(50/0.18), sheath: PVC 10.5φ
Connector type: AMP connector
Receptacle housing: 1-178129-6
Receptacle contact: 1-175218-2
CX26
400T1
400S1
400R1
(A3)
(B2)
(A1)
T
AC400V 3φ S
R