EDIT.
SHEET
DRAW. NO.
CUST.
TITLE
6
93
DESCRIPTIONDESIG.DATE
Power Failure Backup Module
Descriptions
A-53866E-464
2.1.2 400V Input Type
SPM PSM
CNC control power supply
400V
αHV/αHV
i
series amplifiers
SVM
200V
DC link
Submodule C
PSM control power supply
AC reactor
CNC MCC
Device that requires backup
in the event of a power failure
Breaker1
Breaker2
Device that does not require backup in the event of a power failure
(such as an AC fan motor and coolant)
Submodule R
Power failure backup module
(400V input type)
Breaker3
AC fan motor for motor cooling
Breaker4
AC fan motor for amplifier
(1) The power failure backup module (400V input type) is used in combination with
αHV/αHVi series
amplifiers (excluding the PSMV-11HV).
(2) If you use more than one PSM, you need one power failure backup module for each PSM.
(3) Sub module C is required to use the retract function at power failure. Connect as many sub modules C
as are necessary according to the configuration of the machine. See Section 8.2 for an explanation of
the number of sub modules C to be connected.
(4) Sub module R is required to use the stop distance reduction function at power failure. See Section 8.1
for details.
(5) If connecting the power failure backup module to an
α series amplifier, you must always use the
specialized PSM (with #BM specified). See Subsection 2.2.5 for an explanation of the specification
method.
(6) If connecting the power failure backup module to an
αi series amplifier, you can use a standard PSM.
Depending on the number of amplifiers connected, you must supply external control power (24 VDC) to
some of the amplifiers. See Chapter 9 for details.