EDIT.
SHEET
DRAW. NO.
CUST.
TITLE
43
93
DESCRIPTIONDESIG.DATE
Power Failure Backup Module
Descriptions
A-53866E-464
[2] For the α/αHV series amplifier
K5K5
SVM
CX1A CX1B
CX8/CX9
CX2A CX2B
SPM
CX1A CX1B
CX2A CX2B
SVM
CX1A CX1B
CX8/CX9
CX2A CX2B
PSM
CX1A CX1B
CX2A CX2B
DBM
Power failure
backup module
CX12
(CX27)
CX13
(CX28)
CX14
DBM
Uninterruptible power suppl
(UPS) 200V OUT AC200V
Normal operation: Supply 200 VAC.
Power failure: Supply DC voltage (300 VDC).
SPM
CX1A CX1B
CX2A CX2B
AC200V
K78
K4
K65
K64
K4
K93
Built-in fan
24V
Built-in fan Built-in fan Built-in fan Built-in fan
DC power supply
K24
K25
K5
K5
K59
K24
K25
Control
ower su
l
CNC, etc.
Power supply
equipment
(24VDC output)
The specifications of the uninterruptible power supply (UPS) are given below.
The capacity of the UPS to be used depends on the number of dynamic brake modules to be
connected.
UPSs that can be used include the ASE10S1A002 (rated capacity: 1 kVA) of SANYO DENKI Co.,
Ltd.
Specifications of the UPS
Depending on the number of DBMs to be connected, select from among the UPSs with the following
specifications:
Output voltage: Single-phase 200 VAC sine wave
Output frequency: 50/60Hz
Switching time: No instantaneous break
Backup time: Time until machine protection operation is completed in the event
of a power failure (several seconds to several tens of seconds)
Rated output (continuous rating): Number of DBMs x 46 [VA] (if using an
α/αHV SVM)
Number of DBMs x 22 [VA] (if using an
αi/αHVi
SVM)
Overload capacity (20 msec): Number of DBMs x 220 [VA]