EDIT.
SHEET
DRAW. NO.
CUST.
TITLE
29
93
DESCRIPTIONDESIG.DATE
Power Failure Backup Module
Descriptions
A-53866E-464
5.2 CABLE CONNECTION DETAILS
This section provides the details of the cables to be connected to the power failure backup
module.
For details of the connection of the cables between amplifiers and NC and between amplifiers
and motors, refer to the Descriptions B-65282EN or B-65162E.
(1) Details of the connection of short bar K2
This short bar (cable) is used to connect the DC link.
Sub module C
サブモジュールC
DC link To another submodule C
<3>
Power failure backup moduleSVM or SPM
TB1
L+
L-
<2><1>
TB1 TB2 TB1
L+
L-
Film capacitor
Required if submodule R is connected to the power failure backup
module A06B-6077-H002 (200-V type) and cable <1> exceeds 1.5 m.
<1> Connection between the power failure backup module and an amplifier
Connect terminal block TB1
of the power failure backup module to terminal block
TB1 of the SVM or SPM, using the short bar or cable.
Maximum length of cable <1>
1. For the power failure backup module A06B-6077-H002 (200V type)
If sub module R is connected: 5 m max.
If sub module R is not connected: 1.5 m max. (Note)
2. For the power failure backup module A06B-6091-H002 (400V type)
5m max. regardless of whether sub module R is connected or not
Note: By connecting a 3.3 µF, 630 V film capacitor to TB1 of the power failure
backup module, you can extend the length by up to 5m
.
Recommended film capacitor
Manufacturer Product name Type
OKAYA Electric CF99MPP2J335K 3.3 µF / 630V