Power Failure Backup Module
Descriptions
A-53866E-464
(17) Details of the connection of cable K83
This cable is used to supply200 VAC output from CX28 or the voltage (300 VDC) resulting
from stepping down the DC link voltage to the control power input (CX1A) of the PSM
and to the control power supply for the CNC, PMC, and so on.
It is used with the power failure backup module A06B-6091-H002.
For notes on the device to be connected to CX28, see Chapter 3, "Specifications".
Cable type: Vinyl cabtyre cable, JIS C 3312, 2-conductor
Conductor: 1.25mm
2
(50/0.18), sheath: PVC 9.6
φ
Connector type: AMP connector
Receptacle housing: 2-178128-3 (CX28)
1-178128-3 (CX1A)
Receptacle contact: 1-175218-2
Control power supply
for the CNC, PMC, etc
.
CX28
200S
200R
(3)
(2)
(1)
(3)
(2)
(1)
CX1A
200S2(DC-)
200R2(DC+)
200R
200S
Connection of the CNC power unit (PSU)
If you use a PSU with an input of 200 VAC (such as the FS15i), there are cases in which a device other
than the CNC is connected via the PSU. If the device to be connected to the PSU is one that does not
allow input of DC power, connect it directly to200 VAC line.
Power failure backup module
Power failure backup module
CX12 CX13
AC200V
DC24V
CX12 CX13
AC200V
DC24V
Device that cannot be
driven on DC voltage
CNC main body
CNC power unit
CNC power unit
Device that cannot be
driven on DC voltage
CNC main body
OK
NG
CAUTION
The maximum capacity of the power that can be supplied from CX28 is 1000 VA (including up to
300 VA to be supplied to the control power supply for the PSM). Do not connect a loa
exceeding 1000 VA.
At a power failure, the voltage (300 VDC) resulting from stepping down the DC link voltage is
output from CX28. Devices connectable to CX28 are limited to those that can run on DC power.
ever connect a device containing an AC fan motor or AC-driven electromagnetic contactor to