Power Failure Backup Module
Descriptions
A-53866E-464
(4) Resistance regeneration control
After a power failure occurs, causes the energy resulting from the deceleration of the motor to be
consumed in the resistor inside sub module R. In normal operation, the energy resulting from the
deceleration of the motor is regenerated into power, not flowing through the resistor inside sub
module R. For this reason, sub module R does not dissipate heat in normal operation.
(See Subsection 6.2.5.)
Sub module RSVM or SPM Power failure
backup module
PSM
PSM input
voltage
(200 VAC)
Route of regenerated energy in the event of
a
ower failure (resistance re
eneration)
Route of regenerated energy in normal
operation (power regeneration)
Motor
IGBT
Resistor