5.CIMPLICITY VIEWER SETTING B-75074EN/04
- 228 -
(5) Enter the login user name.
Enter the user name for logging in to the i CELL server PC in the
[Connect As] text box (<3>).
(6) Enter the login password.
Enter the password for logging in to the i CELL server PC in the
[Password] text box (<4>).
(7) Click the [Display Server PC Information] button (<5>).
When the viewer PC can be connected to the server PC,
information set on the server PC is displayed in <6> and <7>.
<6>: Name of the shared drive for the i CELL installation
directory
<7>: Name of the shared drive for the NC program root directory
If these names are not displayed, invalid data is entered in step (2),
(5), or (6). Check the data.
(8) When a router is used between the server and viewer PCs, check
[Connect to Server PC's C4 Service] in the [Option] menu.
(9) Click the [Set] button (<8>) to make what you specified effective.
(10) The settings that are made once are effective until they are
canceled.
Restart the viewer PC and log in. The items related to sharing are
set again based on the settings.
When the CIMPLICITY VIEWER Setting Screen is opened on
the viewer PC set once, operations in steps (2), (5), and (6) are
performed automatically.
NOTE
To change an NC program default directory, use the
following procedure:
<1> On i CELL CIMPLICITY VIEWER SETUP,
cancel the CIMPLICITY viewer settings for the
server and viewer PCs.
<2> On the
i CELL Configuration dialog box, change
the default directory.
<3> On i CELL CIMPLICITY VIEWER SETUP,
make the CIMPLICITY viewer settings for the
server and viewer PCs again.