24/98
SHEET
DESCRIPTION
DESIGN
DATE
EDIT
01
FANUC LTD.
DRAW.NO.
Matsukura
Newl
re
istered
TITLE:
FANUC CIMPLICITY i CELL
OPERATOR’S MANUAL
05.05.19
B-75074EN/04-2
i CELLPoint
(reference)
Displays a list of i CELL points currently set
with the control point.
No points are displayed if a new control point
is to be created.
Points are displayed only if i CELL is used.
i CELL Point Count Displays the number of i CELL points
currently set with the control point.
0 if a new control point is to be created.
A number is displayed only if i CELL is used.
5.2.3.3 Editing, deletion, and renaming
This subsection describes each of editing, deletion, and renaming operations.
Each operation can be started by first displaying a list of Point Group
Control Points, described in Subsection 5.2.3.1, "Display".
Editing
Change the points currently set with a control point as follows:
<1> Use either of the following methods to display the Point Group dialog
box:
• Select the control point to edit, and select [Property] from the [Edit]
menu.
• Double-click the control point to edit.
<2> Change settings as desired.
<3> Click the <OK> button.
NOTE
1 The default control point (control point for use with i CELL)
cannot be deleted or renamed.
2 Those control points that have been set in the mail and Web
functions and in the formulas for other points, etc. cannot be
deleted or renamed.