B-75074EN/04 OPERATION 7.WORKPIECE PROCESS RESULTS
- 329 -
Display with workpiece specification
The log data of a specified workpiece only is displayed.
Display with machine and workpiece specification
The log of a specified combination of a machine and workpiece
only is displayed.
The display items are listed below. Note, however, that the display
items vary, depending on the specification.
⋅ Machine (when no machine is specified)
⋅ Workpiece (when no workpiece is specified)
⋅ O number (displayed only in the case of workpiece display)
⋅ Process start time
⋅ Process end time
⋅ Process time
⋅ Process end state
⋅ User area
⋅ Sequence number (only in the case of machine specification)
You can choose whether to display O number and user area data.
NOTE
In connection with display time, all logs satisfying a
condition are not written to a table at a time. Actually,
up to 180 logs (12 pages) can be written to a table at
a time. Six pages are written in the upper and lower
areas with respect to the desired display line
(uppermost display line). So, each time other logs
are to be displayed, those logs need to be obtained
and written to the table, requiring some time for
display. When logs are obtained, the latest
information is obtained. This means that if the
contents of the database change while pages are
switched, the same line does not always display the
same log data as previously displayed.
- Process end state display
The summarized results based on a displayed process end ID set on the
setting screen are displayed. Two types of display are available: table
format and pie chart format.