B-75074EN/04 APPENDIX D.ERROR CODES
- 557 -
0x1004011c(1)
The TCP/IP protocol has not been set up.
Check the Network Protocol tab on Control Panel to see if the TCP/IP protocol has been set up.
Also check whether your PC can share the network with a Windows PC on which the TCP/IP
protocol is already set up and communicate with it using the ping command.
0x1004011c(2)
CDA Manager is not running.
If CDA Manager cannot start normally, check whether "FANUC_PCFA_CDA" has been set up
in the services file.
Each data line in this file must end with a new-line code.
0x1004011d No machine has been specified in the Configuration dialog box.
0x10040121
The folder name is incorrect.
Check the folder name.
0x10040122
There are too many hierarchical levels.
Check the number of hierarchical levels.
0x10040123
Characters that cannot be handled by the NC are included.
Check the character string.
0x10040124
The O number is too long.
Check whether the O number is within the range from 1 to 9999 (1 to 99999999 when 8-digit
numbers are supported).
0x10040125
The file name is too long.
Check the number of characters.
0x10040126
The folder name is too long.
Check the number of characters.
0x10040127 A folder or file name is not specified.
0x10040128
The specified folder of file name (path format) is incorrect.
Check the specified character string.
0x1004020f Communication Manager is not running.
0x10040210 "FANUC_PCFA_APP" has not been set up in the services file.
0x10060001
An attempt was made to open a list file that is already open.
Close the list file, and rerun.
0x10060002
An attempt to open a list file failed.
If you are trying to operate a machine-specific list file, check whether a transfer is completed
and the machine number is valid.
If you are trying to operate an existent original list file, check whether no other process is
operating the same file and the specified file name is correct.
If you are trying to create an original list file, check whether the specified file is correct.
0x10060003
The specified list file was not found.
Check whether the specified list file is valid.
0x10060004 An attempt to close a list file failed.
0x10060005 The specified list file is already closed.
0x10060006
Application software attempted to execute a function (mathematical formula) for a transfer
auxiliary function (instruction sequence).
Check whether the function call is valid.
0x1006000a
The record flag of a specified record is incorrect.
The flag indicates that the function (mathematical formula) you attempted to operate cannot be
executed. Check the record flag.
0x1006000b An attempt to lock the header field failed.
0x1006000c An attempt to lock a specified record field failed.
0x1006000d
A function (mathematical formula) for original list files was executed for a machine-specific list
file.
0x1006000f A function (mathematical formula) for machine-specific files was executed for an original list file.
0x10060010 An attempt to seek a specified record failed.
0x10060011 An attempt to read from a list file failed.
0x10060012
An attempt to read data of an expected size from a list file failed.
Check the contents of the list file.