46/98
SHEET
DESCRIPTION
DESIGN
DATE
EDIT
01
FANUC LTD.
DRAW.NO.
Matsukura
Newl
re
istered
TITLE:
FANUC CIMPLICITY i CELL
OPERATOR’S MANUAL
05.05.19
B-75074EN/04-2
Axis Number
For a non-axis type: 0
For an axis type: Number of axes (equal to or
less than the number of controlled axes)
NOTE1
NOTE1 For an axis type parameter with no axis number specified (Axis
number = 0), an array of axes may be specified. The number of array
elements must be equal to or less than the number of controlled axes.
For an axis type parameter with an axis number specified (Axis
number not equal to 0) and for a non-axis type parameter, set 1 for
Elements.
Specification examples
a) If Point Name: PA3623, Data type: SINT, Bit offset: 0, Elements:
3, Number: 3623, and Axis number: 0
PA3623 (0) = Data for the 1st axis of parameter 3623
PA3623 (1) = Data for the 2nd axis of parameter 3623
PA3623 (2) = Data for the 3rd axis of parameter 3623
b) If Point Name: PA3715A3, Data type: BOOL, Bit offset: 2,
Elements: 1, Number: 3715, and Axis number: 3
PA3715A3 = #2 data for the 3rd axis of parameter 3715
c) If Point Name: PA3715, Data type: BOOL, Bit offset: 2, Elements:
3, Number: 3715, and Axis number: 0
PA3715(0) = #2 data for the 1st axis of parameter 3715
PA3715(1) = #2 data for the 2nd axis of parameter 3715