2.ADDING SCREENS USER CUSTOMIZE B-75074EN/04
- 408 -
2.6.1.2 Public variables
mDirectory
Indicates the directory of a setting file.
- Syntax
object.mDirectory
- Explanation
This variable is of character string type, and its path
is %iCELL%\CimProject\fanuc\.
mDispMachine
Indicates the maximum number of machines.
- Syntax
object.mDispMachine
- Explanation
This variable is of long type, and indicates the maximum number of
machines. This value can be changed only through the setting screen.
This means that this value indicates the number of machines to be
connected by the user. Reference the property pMaxMachine for the
maximum number of machines that can be connected according to the
specification.
When executing the method MachineRead(), allocate areas as many as
this value for the elements of the first dimension of the array.
Do not change the value through an application program.
mErrorMessage
Indicates an error message.
- Syntax
object.mErrorMessage
- Explanation
When the method fails, the cause is written into this variable. This
variable is of character string type.
mLanguage
Indicates a display language.
- Syntax
object.mLanguage
- Explanation
This variable is of long type, and indicates a display language (0:
Japanese, 1: English).
Do not change the value through an application program.