FANUC AC SPINDLE MOTOR a series
2. FUNCTION EXPLANATION
B–65160E/02
110
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
CAXIS3 CAXIS2 CAXIS1
6501 3001 3001 4001
CAXIS1:Determines whether the high-resolution magnetic pulse coder is used
or not.
0: Not used.
1: Used. (Set to 1)
Set to 1 if high–resolution position coder is used.
CAXIS2:Also used in speed detection of the Cs contour control position
detection signal.
0: Not used. (when spindle and spindle motor are separated)
1: Used. (in case of built-in spindle motor)
CAXIS3:Indicates the mounting direction of the Cs contour control position
detector.
0: Rotates the spindle and position detection in the same direction.
1: Rotates the spindle and position detection in the reverse direction.
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
CSDRCT CSDET3 CSDET2 CSDET1
6502 3002 3002 4002
CSDET3-1:
Cs contouring control (resolution) setting.
To be set to 000 usually.
(This parameter is invalid if α sensor Cs contour control is used.)
CSDET3 CSDET2 CSDET1
0 0 0 360000 p/rev.
0 0 1 180000 p/rev.
0 1 0 120000 p/rev.
0 1 1 90000 p/rev.
1 0 0 60000 p/rev.
1 0 1 40000 p/rev.
1 1 0 20000 p/rev.
1 1 1 10000 p/rev.
CSDRCT:
Setting of the rotation direction signal (SFR/SRV) function when Cs
contouring control is used.