B–65160E/02
3. EXPLANATION OF
PARAMETERS
FANUC AC SPINDLE MOTOR a series
241
16i/1615 15i0
Incomplete integration coefficient
6310 3490 3346 4346
6490 3710
Data unit :
Data range : 0 to 32767
Standard setting : 0
When 0 is set in this parameter, complete integration is used.
16i/1615 15i0
Level for detecting a speed difference between spindle 1 and spindle 2
during slave operation
6311 3491 3347 4347
6491 3711
Data unit : 1 min
–1
(10 min
–1
when bit 2 (SPDUNT) of
parameter No. 4006 is set to 1)
Data range : 0 to 32767
Standard setting : 0
Set a level for detecting the signal (MSOVRS) that indicates the speed
difference between spindle 1 and spindle 2 in slave operation.
Set this parameter for the second spindle 2 only.
When 0 is set in this parameter, 100 min
–1
is assumed.
16i/1615 15i0
Overload current alarm detection level (for low-speed range)
6312 3492 3348 4348
6492 3712
Data unit :
Data range : 0 to 32767
Standard setting : Depends on the motor model.
16i/1615 15i0
Overload current alarm detection time constant
6313 3493 3349 4349
6493 3713
Data unit : 1 second
Data range : 0 to 32767
Standard setting : Depends on the motor model.
16i/1615 15i0
Overload current alarm detection level (for high-speed range)
6314 3494 3350 4350
6494 3714
Data unit :
Data range : 0 to 32767
Standard setting : Depends on the motor model.