B–65160E/02
1. ADJUSTMENT
FANUC AC SPINDLE MOTOR a series
5
Parameter No.
0 15
Description
1st
spindle
2nd
spindle
1st
spindle
2nd
spindle
15i 16i/16
Description
–
(*1)
–
(*1)
5606
#0
5606
#1
5606
#0
–
(*1)
Whether to use a
series (Serial)
spindle amplifiers
0071
#4
5604
#0
5841
(*2)
3701
#4
Number of a
series (Serial)
spindle amplifiers
connected
*1 Optional parameter
*2 For Series 15–i, specify an axis number in No. 5841.
(1) Parameter list
Parameter No.
0 15
Description
1st
spindle
2nd
spindle
1st
spindle
2nd
spindle
15i 16i/16
Description
6519
#7
6659
#7
5607
#0
5607
#1
5607
#0
4019
#7
Function for auto-
matically initializ-
ing a series (Seri-
al) spindle param-
eters
6633 6773 3133 3273 3133 4133 Motor model code
When spindle switching control is used with a single spindle amplifier to
switch between two motors, see Section 2.7 for information about
automatic parameter initialization for the motor on the subspindle side.
(2) Procedure for automatic spindle parameter initialization
Perform automatic spindle parameter initialization by following the
procedure below.
1. Set the model code for the desired motor for automatic parameter
initialization. The model codes are listed in Appendix C.
For a motor for which there is no model code, follow the
procedure below.
(a) Perform automatic parameter initialization using a model
code for which the parameter data is similar, then manually
change the parameter data as required.
1.2
PARAMETERS
RELATED TO
START–UP
1.2.1
Parameters for the a
Series (Serial) Spindle
System
1.2.2
Automatic Spindle
Parameter Initialization