FANUC AC SPINDLE MOTOR a series
3. EXPLANATION OF
PARAMETERS
B–65160E/02
182
NOTE
With FS15/15i, the different parameter address, bit 0 of
parameter No. 5607, is used for this function.
Note also that the setting function is reversed.
0: Automatic parameter initialization is performed.
1: Automatic parameter initialization is not performed.
Set a model code in parameter No. 3133.
16i/1615 15i0
Maximum speed
6520 3020 3020 4020
6660 3160
Data unit : 1 min
–1
(when parameter No. 4006 #2 (SPDUNT)
= 1, 10 min
–1
)
Data range : 0 to 32767
Standard setting : Depends on a motor model.
This data is used to set the maximum speed of AC spindle motor.
16i/1615 15i0
Maximum speed in Cs contouring control
6521 3021 3021 4021
6661 3161
Data unit : 1 min
–1
(when parameter No. 4006 #2 (SPDUNT)
= 1, 10 min
–1
)
Data range : 0 to 32767
Standard setting : 100
Set maximum spindle speed in Cs contouring control.
16i/1615 15i0
Speed arrival detection level
6522 3022 3022 4022
6662 3162
Data unit : 0.1%
Data range : 0 to 1000 (0 to 100%)
Standard setting : 150 (15%)
This data is used to set the detecting range of speed arrival signal (SARA).
When the motor speed reaches the range within ^ (setting data/10)% of
commanded speed, the bit of speed arrival signal (SARA) is set to ”1”.