B–65160E/02
2. FUNCTION EXPLANATION
FANUC AC SPINDLE MOTOR a series
153
(1) Input signals (PMC ³ CNC)
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
MRDYA ORCMA SFRA SRVA CTH1A CTH2A TLMHA TLMLA
G229 G227 G227 G070
G233 G235 G235 G074
1st–
2nd–
RCHA RSLA INTGA SOCNA MCFNA SPSLA *ESPA ARSTA
G230 G226 G226 G071
G234 G234 G234 G075
1st–
2nd–
RCHHGA MFNHGA INCMDA OVRA DEFMDA NRROA ROTAA INDXA
G231 G229 G229 G072
G235 G237 G237 G076
1st–
2nd–
(2) Output signals (CNC ³ PMC)
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
ORARA TLMA LDT2A LDT1A SARA SDTA SSTA ALMA
F281 F229 F229 F045
F285 F245 F245 F049
1st–
2nd–
RCFNA RCHPA CFINA CHPA
F282 F228 F228 F046
F286 F244 F244 F050
1st–
2nd–
Parameter No.
0 15
Description
Main spindle
1st
spindle
2nd
spindle
1st
spindle
2nd
spindle
15i 16i/16
side/
sub spindle
side
6519 #7 6659 #7 5607 #0 5607 #1 5607 #0 4019 #7
Automatic
parameter
initialization
function
Main spindle
side
6633 6773 3133 3273 3133 4133 Model code
6159 #7 6339 #7 5607 #0 5607 #1 5607 #0 4195 #7
Automatic
parameter
initialization
function
Sub spindle
side
6273 6453 3453 3673 3309 4309 Model code
6514 #0 6654 #0 3014 #0 3154 #0 3014 #0 4014 #0
Whether to use the spindle
switching control function
(Set this bit to 1.)
6514 #2 6654 #2 3014 #2 3154 #2 3014 #2 4014 #2
Function for checking the
contacts of the
electromagnetic contactors for
the main spindle and sub
spindle sides, subject to
spindle switching
6514 #1 6654 #1 3014 #1 3154 #2 3014 #1 4014 #1
Spindle switching function
during sub spindle rotation
2.8.2
DI/DO Signals Related
to Spindle Switching
Control
2.8.3
Parameters Related to
Spindle Switching
Control