B–65160E/02
B. LIST OF SPINDLE PARAMETER
NUMBERS
APPENDIX
349
1st spindle
Contents
2nd spindle
Spindle switching
MAIN side
Contents
Spindle switching
SUB side
Spindle switching
MAIN side
Spindle switching
SUB side
High
–speed
charac-
teristics
Contents
Low
–speed
charac-
teristics
High
–speed
charac-
teristics
Low
–speed
charac-
teristics
High
–speed
charac-
teristics
Low
–speed
charac-
teristics
High
–speed
charac-
teristics
Low
–speed
charac-
teristics
3088 ² ² ² 3228 ² ² ² Level for detecting excess velocity devi-
ation when motor is restrained
3089 ² ² ² 3229 ² ² ² Level for detecting excess velocity devi-
ation when motor rotates
3090 ² ² ² 3230 ² ² ² Overload detection level
3091 ² 3383 ² 3231 ² 3603 ² Rate of change in position gain during ref-
erence position return in servo mode
3092 ² ² ² 3232 ² ² ² Rate of change in position gain during ref-
erence position return in Cs contour con-
trol mode
3094 ² 3234 ² Disturbance torque compensation
constant
3095 ² ² ² 3235 ² ² ² Adjusted output voltage of speedometer
3096 ² ² ² 3236 ² ² ² Adjusted output voltage of load meter
3097 ² 3237 ² Feedback gain of spindle speed
3098 ² ² ² 3238 ² ² ² Maximum speed of position coder signal
detection
3099 ² ² ² 3239 ² ² ² Motor activation delay
3100 3282 3400 3430 3240 3502 3620 3650 Conventional : Base speed of motor out-
put specifications
HRV : Base speed of motor output specifi-
cations
3101 3283 3401 3431 3241 3503 3621 3651 Conventional : Output limit for motor out-
put specifications
HRV : Torque–limit for motor output speci-
fications
3102 3284 3402 3432 3242 3504 3622 3652 Conventional : Base speed
HRV : Activating voltage saturation speed
at no–load
3103 3285 3403 3433 3243 3505 3623 3653 Conventional : Speed at which decrease
in magnetic flux begins
HRV : Base speed limit ratio
3104 3286 3404 3434 3244 3506 3624 3654 Conventional : Proportional gain of current
loop
HRV : Proportional gain of current loop
3105 ° 3245 ° Conventional : Proportional gain of current
loop (in Cs contour control mode)
HRV :
3106 3287 3405 3435 3246 3507 3625 3655 Conventional : Integral gain of current
loop
HRV : Integral gain of current loop
3107 ° 3247 ° Conventional : Integral gain of current
loop (in Cs contour control mode)
HRV :