FANUC AC SPINDLE MOTOR a series
2. FUNCTION EXPLANATION
B–65160E/02
74
Orientation completion signal detection level
6575 3075 3075 4075
6715 3215
1st–
2nd–
Data unit : Position coder method → "1 pulse unit
Magnetic sensor method → "0.1 degree unit
Data range : 0 to 100
Standard setting : 10
This data is used to set the detecting level of orientation completion
signal (ORARA).
When the spindle position is located within the setting data on
orientation completion, the bit of orientation completion signal
(ORARA) in the spindle control signals is set to ”1”.
16i/160
15 15i
Motor speed limit value on orientation
6576 3076 3076 4076
6716 3216
1st–
2nd–
Data unit : 1%
Data range : 0 to 100
Standard setting : 33
This data is used to set the motor speed limit value on orientation.
Orientation speed of motor = Position gain Gear ratio 60 min
–1
Speed limit value = Orientation speed of motor (Setting data)/100
min
–1
16i/160
15 15i
Orientation stop position shift value
6577 3077 3077 4077
6717 3217
1st–
2nd–
Data unit : Position coder method → "1 pulse unit
Magnetic sensor method → "0.01 degree unit
Data range : Position coder method → – 4095 to 4095
Magnetic sensor method → –100 to 100
Standard setting : 0
In the position coder method orientation, set this data to shift stop
position.
Spindle is shift No. of setting pulse in CCW direction, and stops by
data (+).