B–65160E/02
3. EXPLANATION OF
PARAMETERS
FANUC AC SPINDLE MOTOR aC series
281
16i/16
#7 #6 #5 #4 #3 #2 #1 #0
0
15i
15
NRROEN
6517 3017 3017 4017
6657 3157
Standard setting: 0 0 0 0 0 0 0 0
NRROEN:
Specifies whether the shortcut function is used when the spindle
orientation by position coder is performed from the stop state.
0: Not used.
1: Used.
When this bit is set to “1”, the shortcut function is used when the following
requirements are satisfied.
D Parameter NO.4016#7 (RFCHK3) =“0”
D Speed zero detection signal (SST) =“1”
D The shortcut command NRRO =“1”
16i/16
#7 #6 #5 #4 #3 #2 #1 #0
0
PRLOAD6519 4011
6659
Standard setting: 0 0 0 0 0 0 0 0
PRLOAD:
Parameter automatic setting function (Series 0, Series 16, 18, 20, 21,
Power Mate)
0: Parameter automatic setting function is not executed
1: Parameter automatic setting function is executed
Set the model code parameter PRM6633 (Series0),PRM4133 (Series16
etc.),,and set this bit to “1”. Then turn the CNC off, then on again. The
spindle parameters are automatically initialized. Upon the completion of
automatic parameter initialization , this bit automatically reset to “0”.
NOTE
With Series 15, the different parameter address,
PRM5607#0 is used this function. Note also that setting
function is reversed. Set the model code parameter
PRM3133 (Series 15).
0: Parameter automatic setting function is executed
1: Parameter automatic setting function is not executed