B-63924EN/01 APPENDIX A.SCREEN-SPECIFIC CNC SETTINGS
- 337 -
25. [PMC Keep Relay] screen
CNC supported FS30i/31i/32i
Optional function None (basic)
Settin
s re
uired
for screen dis
la
modification and
operation
Display of the [Switch PMC] operation key
When multiple PMC paths are used
Display of PMC keep relay data
→ When the 8-level data protection function is enabled
Displayed unconditionally
→ When the 8-level data protection function is disabled
When the programmer function is enabled (K900.1 = 1), or
When PMC parameter reference is disabled (K902.6 = 0)
Editing of PMC keep relay data
→ When the 8-level data protection function is enabled
When the operation level is not lower than the keep relay chan
e
protect level
→ When the 8-level data protection function is disabled
- MDI mode
- When the programmer function is enabled (K900.1 = 1), or
When PMC parameter modification is disabled (K902.7 = 0)
Display of PMC keep relay system data (K900 and up)
→ When the 8-level data protection function is enabled
Displayed unconditionally
→ When the 8-level data protection function is disabled
When the programmer function is enabled (K900.1 = 1), or
When PMC parameter reference is disabled (K902.6 = 0)
Editing of PMC keep relay system data (K900 and up)
→ When the 8-level data protection function is enabled
When the operation level is not lower than the keep relay (system)
change protect level
→ When the 8-level data protection function is disabled
- MDI mode
- When the programmer function is enabled (K900.1 = 1), or
When PMC parameter modification is disabled (K902.7 = 0) and editing
is enabled (K901.6 = 1)
26. [PMC Data] screen
CNC supported FS30i/31i/32i
Optional function None (basic)
Settin
s re
uired
for screen dis
la
modification and
operation
Display of the [Switch PMC] operation key
When multiple PMC paths are used
Editing of the table data of PMC data
When the 8-level data protection function is disabled, or
When the 8-level data protection function is enabled and the operation
level is not lower than the change protect level
Display of PMC data
→ When the 8-level data protection function is enabled
Displayed unconditionally
→ When the 8-level data protection function is disabled
When the programmer function is enabled (K900.1 = 1), or
When PMC parameter reference is disabled (K902.6 = 0)
Editing of PMC data
→ When the 8-level data protection function is enabled
When the operation level is not lower than the change protect level
→ When the 8-level data protection function is disabled
- MDI mode
- When the programmer function is enabled (K900.1 = 1), or
When PMC parameter modification is disabled (K902.7 = 0)